Table 4: Comparison between experimental and simulated coincidence summing correction factors for Marinelli beaker source.

Volume (ml) Energy (keV) CSFExp CSFCal CSFSimu RD (%)
450 1173.24 0.875 0.901 0.880 -0.5
1332.50 0.858 0.900 0.867 -0.1
898.02 0.909
1836.01 0.847
600 1173.24 0.874 0.906 0.882 -0.9
1332.50 0.867 0.905 0.871 -0.4
898.02 0.901
1836.01 0.831
800 1173.24 0.872 0.909 0.886 -1.6
1332.50 0.868 0.908 0.875 -0.8
898.02 0.896
1836.01 0.824
1000 1173.24 0.884 0.911 0.889 -0.5
1332.50 0.877 0.910 0.891 -1.5
898.02 0.893
1836.01 0.812