Table 6: HVOF coatings metallographic examination data.

Sample

 

 

Porosity

Unmelted particle

Interface contamination

Oxides

Interface Separation

Cracks

Rockwell Hardness

(HR15 N scale)

Stellite grade 1

< 1%

Absent

< 0.5%

< 1%

No separation

No Cracks

90.83 ± 0.75

Tungsten Carbide

< 1%

Absent

< 0.5%

< 1%

No separation

No Cracks

93.16 ± 1.17

Colmonoy 6

< 1%

Absent

< 0.5%

< 1%

No separation

No Cracks

89 ± 1.09